EXPEC-2000 VOC system is based on the principle of gas chromatography technology(GC-FID),it is of capable monitoring characteristic factors such as methane/non-methane hydrocarbons and benzene etc.
Mercury analyzer applies cold vapor atomic fluorescence technology(CVAFS), integrated with dilution sampling system to eliminate interference with
background components and ensure reliable performance. Automatic calibration of mercury check with internal CAL-200 calibration gas generator.
CEMS-4000 VOC is an online emission monitoring system based on catalytic oxidation-FID technology, which can monitor volatile organic compounds (including total hydrocarbons, non-methane total hydrocarbons, etc.) in the flue gas. The system supports multiple installation methods, including wall-mounted installation, platform installation, cabin-type installation, etc. It can be widely used in the oil and gas industry, electronics industry, automobile manufacturing industry, and pharmaceuticals industry.
CEMS-2000 B FT system uses direct thermal wet extraction method based on FTIR gas analysis technology, the system mainly has three major components: sampling pre-process-ing system, FTIR gas analyzer,and data acquisition and processing unit. The system can simultaneously monitor multiple groups of components in flue gas such as SO, NO, NO2, NOx, NH3, HCL, HF, O2, CO, CO2, CH4, H2O,etc. It is especially suitable for waste incineration.
FPI CEMS-2000D is an automatic dilution extractive system ranging in dilution ratios from 20:1 to over 400:1, designed for SOx, NOx, O2, H2O, and meteorological parameters monitoring, ensuring consistent reliability, repeatability and precise measurement in the application of smelting, power generation, steel, and chemical.